Every camera and IMU we have calibrated, by who made the chip. A label names a part only when the device maker, the dataset authors or a published teardown names it. Otherwise it says “not known”; we don’t guess. A measurement gives the frame rate, not the chip, so it never names a part.
Maker: the device maker’s datasheet, product page, manual or written statement names the part. A private source has no link.
Dataset: the dataset authors, or the device’s own calibration file in the dataset, name it.
Teardown: a published teardown or trade article names it; the maker has not.
Module: a packaged IMU module (Xsens, MicroStrain). We name the module; no source names the chip inside.
19devices calibrated
45 + 19cameras + IMUs on them
5chip makers named
13 / 64parts not known
Image sensors35 of 45 cameras named, on the devices below
OmniVision 17SmartSens 15Sony 3not known 10
IMU chips16 of 19 IMUs named, on the devices below
Bosch 8TDK InvenSense 8not known 3
OmniVision
Image sensors · 17 cameras on devices · 14 in datasets
SonyIMX283×2ONE RS firmware (IMX283 dual sensor driver) · the firmware names the driver, not the lens; the 1-Inch 360 is the only ONE RS lens with two 1-inch sensors
TDK InvenSenseICM-40609gyro type in the metadata of a 1-Inch 360 sample video (360 Rumors) · the camera writes its gyro type into every video; the ONE RS firmware supports ICM-20948 and ICM-40609
7 evaluations. A part used in several evaluations is counted in each; the tiles above count devices only.