Monado MIC (Valve Index) results
Repeatability, not accuracy. There is no ground truth: a small spread shows that a tool repeats, not that it is right, and a difference shows that two tools disagree, not which one is wrong. We ran every tool ourselves, including Kalibr and Basalt.
- Chart centre. Each chart is centred on the Monado authors' own Basalt calibration of this headset, made from one recording: extras/calibration.raw.json for the camera–IMU distance, baseline and time offset, and its kb4 version (calibration.json) for the intrinsics. Their IMU terms are not used: the released recordings appear to carry the authors' IMU correction already, so those charts, and t_ga, are centred on the MVIS median.
MIC-cam · camera only
Section titled “MIC-cam · camera only”cam0 + cam1 stereo · 8 recordings
Read first: Each tool calibrates both cameras and their baseline from the images alone, on the 8 camcalib recordings.
Coverage
Section titled “Coverage”- MVIS 8 of 8
- Kalibr 8 of 8
- Basalt 8 of 8
Parameters by sensor
Section titled “Parameters by sensor”2 sensors, 17 parameter charts (each tool's spread; click to fold)
fx px axis 421 ± 5.9 · centre: reference
fy px axis 421 ± 5.69 · centre: reference
cx px axis 469 ± 2.16 · centre: reference
cy px axis 479 ± 0.862 · centre: reference
dist k1 axis 0.193 ± 0.0669 · centre: reference
dist k2 axis 0.0421 ± 0.212 · centre: reference
dist k3 axis −0.233 ± 0.262 · centre: reference
dist k4 axis 0.0954 ± 0.111 · centre: reference
fx px axis 421 ± 7.53 · centre: reference
fy px axis 421 ± 7.21 · centre: reference
cx px axis 468 ± 2.8 · centre: reference
cy px axis 484 ± 0.986 · centre: reference
dist k1 axis 0.19 ± 0.0234 · centre: reference
dist k2 axis 0.0547 ± 0.081 · centre: reference
dist k3 axis −0.249 ± 0.113 · centre: reference
dist k4 axis 0.103 ± 0.0518 · centre: reference
baseline to Valve Index cam0 mm axis 134 ± 0.246 · centre: reference
Whisker = lowest to highest value over the tool's solved recordings; box = median ± sd; tick = median. Min and max come from the per-recording values behind each record's median; only these two numbers are published, not the values. Rotations are not shown: the records do not hold them yet.
MIC · camera + IMU
Section titled “MIC · camera + IMU”cam0 + cam1 + IMU · 8 recordings
Read first: Kalibr's intrinsics and baselines are inputs from its own camera-only calibration; its td, lever and IMU intrinsics are solved given them.
Coverage
Section titled “Coverage”- MVIS 8 of 8
- Kalibr 8 of 8
- Basalt 8 of 8
For a fair comparison, MVIS is run here with Kalibr's IMU model, so its gyro and accel terms mean the same as Kalibr's. MVIS still estimates t_ga and refines the camera intrinsics.
Fit: reprojection median, px (fit of each tool's own model, not accuracy)
| Camera | MVIS | Kalibr | Basalt |
|---|---|---|---|
| Valve Index cam0 | 0.227 | 1.114 | – |
| Valve Index cam1 | 0.221 | 0.360 | – |
Parameters by sensor
Section titled “Parameters by sensor”3 sensors, 31 parameter charts (each tool's spread; click to fold)
fx px axis 421 ± 3.66 · centre: reference
fy px axis 421 ± 3.35 · centre: reference
cx px axis 469 ± 1.29 · centre: reference
cy px axis 479 ± 1.01 · centre: reference
dist k1 axis 0.193 ± 0.0307 · centre: reference
dist k2 axis 0.0421 ± 0.106 · centre: reference
dist k3 axis −0.233 ± 0.137 · centre: reference
dist k4 axis 0.0954 ± 0.0606 · centre: reference
time offset td to base IMU ms axis −0.335 ± 0.577 · centre: reference · line at 0
distance to base IMU ‖p‖ mm axis 140 ± 3.95 · centre: reference
fx px axis 421 ± 3.11 · centre: reference
fy px axis 421 ± 3.05 · centre: reference
cx px axis 468 ± 1.96 · centre: reference
cy px axis 484 ± 0.784 · centre: reference
dist k1 axis 0.19 ± 0.0178 · centre: reference
dist k2 axis 0.0547 ± 0.0651 · centre: reference
dist k3 axis −0.249 ± 0.0939 · centre: reference
dist k4 axis 0.103 ± 0.0467 · centre: reference
baseline to Valve Index cam0 mm axis 134 ± 0.173 · centre: reference
time offset td to base IMU ms axis −0.335 ± 0.643 · centre: reference · line at 0
distance to base IMU ‖p‖ mm axis 71.5 ± 1.99 · centre: reference
gyro Dw[0,0] scale x axis 0.988 ± 0.00794 · centre: MVIS median
gyro Dw[1,1] scale y axis 0.991 ± 0.00552 · centre: MVIS median
gyro Dw[2,2] scale z axis 1 ± 0.000572 · centre: MVIS median
gyro Dw[1,0] cross axis −0.00482 ± 0.00209 · centre: MVIS median
gyro Dw[2,0] cross axis −0.00491 ± 0.00358 · centre: MVIS median
gyro Dw[2,1] cross axis −0.00547 ± 0.00147 · centre: MVIS median
accel Da[0,0] scale x axis 1.06 ± 0.0971 · centre: MVIS median · line at 1
accel Da[1,1] scale y axis 1.06 ± 0.084 · centre: MVIS median · line at 1
accel Da[2,2] scale z axis 1.07 ± 0.0917 · centre: MVIS median · line at 1
t_ga gyro−accel ms axis −0.876 ± 0.253 · centre: MVIS median
Whisker = lowest to highest value over the tool's solved recordings; box = median ± sd; tick = median. Min and max come from the per-recording values behind each record's median; only these two numbers are published, not the values. Rotations are not shown: the records do not hold them yet.